beautypg.com

Read inspection results – Rockwell Automation 5370 CVIM Communications Manual User Manual

Page 82

background image

Chapter 5

Using the RS–232 Ports

5–12

Use this command to read the results of the last inspection. Refer to
Appendix B for a description of the results blocks. Use the following
commands:

>RRx,TSno,d [CR]

Where:

x

=

Number of times command is repeated.

n

=

Toolset number TS1, TS2, or S
(CVIM module status)

o

=

RL (specifies Reference Line)
RW (specifies Reference Window)
G (specifies Gage)
W (specifies Window)
LP (specifies Light Probe)

d

=

Gage, Window, Reference Line, or
Reference Window number.

>RRx, TS1 [CR]

Reads discrete bit results for toolset 1.

x = Number of times command is repeated.

>RRx,TS2 [CR]

Reads discrete bit first results for toolset 2.
x = Number of times command is repeated.

>RRx,TS1RB,d [CR]

Reads results block(s) for toolset 1
x = Number of times command is repeated.
d = Block number.

>RRx,TS2RB,d [CR]

Reads results block(s) for toolset 2.
x = Number of times command is repeated.
d = Block number.

>RRx, S [CR]

Reads CVIM module status.

Read Inspection Results