Load initial configuration values chapter 7 – Rockwell Automation 1771-QDC, D17716.5.87(Passport) CLAMP AND EJECT MODE User Manual
Page 99

Enter Your Values Here
Load Initial Configuration Values
Chapter 7
7-23
Worksheet 7ĆJ (continued)
Ejector Retract (ERC) Configuration Block
Control Word ProĆSet 600 Addr. Value
Description
Units
ERC05
N45:61
1000
Minimum ERC
PercentageĆĆVelocity
Percent
8
ERC06
N45:62
1000
Minimum ERC
PercentageĆĆPressure
Percent
8
ERC09
N45:65
*
Output #1 SetĆOutput Value during Retract
Percent Signal Output
4
ERC10
N45:66
*
Output #2 SetĆOutput Value during Retract
Percent Signal Output
4
ERC11
N45:67
*
Output #3 SetĆOutput Value during Retract
Percent Signal Output
4
ERC12
N45:68
*
Output #4 SetĆOutput Value during Retract
Percent Signal Output
4
ERC17
N45:73
0
Output #1 Acceleration Ramp Rate during Retract
Percent Signal Output per Second
5
ERC18
N45:74
0
Output #2 Acceleration Ramp Rate during Retract
Percent Signal Output per Second
5
ERC19
N45:75
0
Output #3 Acceleration Ramp Rate during Retract
Percent Signal Output per Second
5
ERC20
N45:76
0
Output #4 Acceleration Ramp Rate during Retract
Percent Signal Output per Second
5
ERC25
N45:81
0
Output #1 Deceleration Ramp Rate during Retract
Percent Signal Output per Second
5
ERC26
N45:82
0
Output #2 Deceleration Ramp Rate during Retract
Percent Signal Output per Second
5
ERC27
N45:83
0
Output #3 Deceleration Ramp Rate during Retract
Percent Signal Output per Second
5
ERC28
N45:84
0
Output #4 Deceleration Ramp Rate during Retract
Percent Signal Output per Second
5
ERC33
N45:89
*
Output #1 SetĆOutput Value at EndĆof Retract
Percent Signal Output
4
ERC34
N45:90
*
Output #2 SetĆOutput Value at EndĆof Retract
Percent Signal Output
4
ERC35
N45:91
*
Output #3 SetĆOutput Value at EndĆof Retract
Percent Signal Output
4
ERC36
N45:92
*
Output #4 SetĆOutput Value at EndĆof Retract
Percent Signal Output
4
ERC41
N45:97
0
Pressure Minimum Control Limit
Pressure
3
ERC42
N45:98
System Pressure
Pressure Maximum Control Limit
Pressure
3
ERC43
N45:99
*
Selected Pressure Valve Output for Minimum
Percent Signal Output
4
ERC44
N45:100
*
Selected Pressure Valve Output for Maximum
Percent Signal Output
4
ERC45
N45:101
0
Velocity Minimum Control Limit
Velocity along Axis
2
ERC46
N45:102
Max Velocity per
OEM specs*
Velocity Maximum Control Limit
Velocity along Axis
2
ERC47
N45:103
*
Selected Velocity Valve Output for Minimum
Percent Signal Output
4
ERC48
N45:104
*
Selected Velocity Valve Output for Maximum
Percent Signal Output
4
ERC49
N45:105
100
Proportional Gain for Pressure Control
None
ERC50
N45:106
400
Integral Gain for Pressure Control
Inverse Time (Algorithm)
6
ERC51
N45:107
0
Derivative Gain for Pressure Control
Time (Algorithm)
7
Time
1
ERC52
N45:108
200
Proportional Gain for Velocity Control
Inverse Time (Algorithm)
6
ERC53
N45:109
0
Feed Forward Gain for Velocity Control
None
1
Time
2
Velocity along Axis
3
Pressure
4
Percent Signal Output
00.00 to 99.99 Seconds 00.00 to 99.99 Inches per Second 0000 to 9999 PSI 00.00 to 99.99
000.0 to 999.9 Millimeters per Sec 000.0 to 999.9 Bar
5
Percent Signal Output per Second
6
Inverse Time (Algorithm)
7
Time (Algorithm)
8
Percent
0000 to 9999 00.00 to 99.99 Minutes 00.00 to 99.99 Minutes 00.00 to 99.99
00.00 to 99.99 Seconds
*Refer to the appropriate section later in this chapter for information on this parameter