Select Command and Status Bits

to Sequence Machine Operation

Chapter 6

6-8

Table 6.J

Command and Configuration Bits for Clamp and Eject Mode

Operation:

Function Enabled

(when = 1):

QDC Block

Addr.:

ProĆSet

Addr.:

NonĆprofiled

execute setĆoutput

DYC01ĆB08

B35/392

Action Commands execute unassigned # 1 jog

DYC01ĆB09

B35/393

execute unassigned # 2 jog

DYC01ĆB10

B35/394

execute unassigned # 3 jog

DYC01ĆB11

B35/395

execute clamp forward jog

DYC01ĆB12

B35/396

execute clamp reverse jog

DYC01ĆB13

B35/397

execute ejector advance jog

DYC01ĆB14

B35/398

execute ejector retract jog

DYC01ĆB15

B35/399

Profile Action

execute 1st clamp close profile

DYC02ĆB00

B35/400

Commands

execute 2nd clamp close profile

DYC02ĆB01

B35/401

execute 3rd clamp close profile

DYC02ĆB02

B35/402

execute LP clamp close profile

DYC02ĆB03

B35/403

execute 1st clamp open profile

DYC02ĆB10

B35/410

execute 2nd clamp open profile

DYC02ĆB11

B35/411

execute 3rd clamp open profile

DYC02ĆB12

B35/412

execute clamp open slow profile

DYC02ĆB13

B35/413

execute ejector profile

DYC02ĆB14

B35/414

Stop Command

execute all stop (outputs = zero)

DYC02ĆB15

B35/415

Miscellaneous

reset tonnage watchdog timer

DYC03ĆB00

B35/416

Commands

reset SYS01ĆB08

DYC03ĆB08

B35/424

reset latched alarms

DYC03ĆB09

B35/425

reset complete bits

DYC03ĆB10

B35/426

continue ejector profile

DYC03ĆB15

B35/431

Logical Bridge

setĆoutput @ endĆof 1st clamp close profile

(0 = start 2nd clamp close profile)

CPC03ĆB08

B37/296

setĆoutput @ endĆof 2nd clamp close profile

(0 = start 3rd clamp close profile)

CPC03ĆB09

B37/297

setĆoutput @ endĆof 3rd clamp close profile

(0 = start clamp LP close profile)

CPC03ĆB10

B37/298

setĆoutput @ endĆof 1st clamp open profile

(0 = start 2nd clamp open profile)

OPC03ĆB08

B37/616

setĆoutput @ endĆof 2nd clamp open profile

(0 = start 3rd clamp open profile)

OPC03ĆB09

B37/617

setĆoutput @ endĆof 3rd clamp open profile

(0 = start clamp open slow profile)

OPC03ĆB10

B37/618

setĆoutput @ endĆof all ejector strokes

(0 = start each new stroke @ end of previous)

EPC03ĆB12

B39/172