beautypg.com

Load initial configuration values chapter 7 – Rockwell Automation 1771-QDC, D17716.5.87(Passport) CLAMP AND EJECT MODE User Manual

Page 91

background image

Enter Your Values Here

Load Initial Configuration Values

Chapter 7

7-15

Worksheet 7ĆF (continued)
Second Clamp Open (SOC) Configuration Block

Control Word ProĆSet 600 Addr. Value

Description

Units

SOC05

N43:361

1000

Minimum ERC

PercentageĆĆVelocity

Percent

8

SOC06

N43:362

1000

Minimum ERC

PercentageĆĆPressure

Percent

8

SOC08

N43:364

0

Profile Watchdog Timer Preset

Time

1

SOC09

N43:365

*

Output #1 SetĆOutput Value during Profile

Percent Signal Output

3

SOC10

N43:366

*

Output #2 SetĆOutput Value during Profile

Percent Signal Output

3

SOC11

N43:367

*

Output #3 SetĆOutput Value during Profile

Percent Signal Output

3

SOC12

N43:368

*

Output #4 SetĆOutput Value during Profile

Percent Signal Output

3

SOC17

N43:373

0

Output #1 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

4

SOC18

N43:374

0

Output #2 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

4

SOC19

N43:375

0

Output #3 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

4

SOC20

N43:376

0

Output #4 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

4

SOC25

N43:381

0

Output #1 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

4

SOC26

N43:382

0

Output #2 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

4

SOC27

N43:383

0

Output #3 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

4

SOC28

N43:384

0

Output #4 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

4

SOC33

N43:389

*

Output #1 SetĆOutput Value at EndĆof Profile

Percent Signal Output

3

SOC34

N43:390

*

Output #2 SetĆOutput Value at EndĆof Profile

Percent Signal Output

3

SOC35

N43:391

*

Output #3 SetĆOutput Value at EndĆof Profile

Percent Signal Output

3

SOC36

N43:392

*

Output #4 SetĆOutput Value at EndĆof Profile

Percent Signal Output

3

SOC41

N43:397

0

Pressure Minimum Control Limit

Pressure

2

SOC42

N43:398

System Pressure

Pressure Maximum Control Limit

Pressure

2

SOC43

N43:399

*

Selected Pressure Valve Output for Minimum

Percent Signal Output

3

SOC44

N43:400

*

Selected Pressure Valve Output for Maximum

Percent Signal Output

3

SOC45

N43:401

0

Velocity Minimum Control Limit

Velocity along Axis

5

SOC46

N43:402

Max Velocity per

OEM specs*

Velocity Maximum Control Limit

Velocity along Axis

5

SOC47

N43:403

*

Selected Velocity Valve Output for Minimum

Percent Signal Output

3

SOC48

N43:404

*

Selected Velocity Valve Output for Maximum

Percent Signal Output

3

SOC49

N43:405

100

Proportional Gain for Pressure Control

None

SOC50

N43:406

400

Integral Gain for Pressure Control

Inverse Time (Algorithm)

6

SOC51

N43:407

0

Derivative Gain for Pressure Control

Time (Algorithm)

7

Time

1

SOC52

N43:408

200

Proportional Gain for Velocity Control

Inverse Time (Algorithm)

6

SOC53

N43:409

0

Feed Forward Gain for Velocity Control

None

SOC57

N43:413

0

Profile High Pressure Alarm Setpoint

Pressure

2

1

Time

2

Pressure

3

Percent Signal Output

4

Percent Signal Output per Second

00.00 to 99.99 Seconds 0000 to 9999 PSI 00.00 to 99.99 0000 to 9999

000.0 to 999.9 Bar

5

Velocity along Axis

6

Inverse Time (Algorithm)

7

Time (Algorithm)

8

Percent

00.00 to 99.99 Inches per Second 00.00 to 99.99 Minutes 00.00 to 99.99 Minutes 00.00 to 99.99

000.0 to 999.9 Millimeters per Sec 00.00 to 99.99 Seconds

*Refer to the appropriate section later in this chapter for information on this parameter