Enter Your Initial Values Here
Jog Your Machine
Chapter 5
5-2
Worksheet 5-A outlines all values necessary to successfully configure your
QDC module for clamp and ejector jogs. Enter initial values to allow
minimal actuator motion during jogs. Later in this chapter, we gradually
increase these values until we reach the desired jog values.
At this time, also enter in jog high pressure setpoints in Worksheet 5-A.
The QDC module sets an alarm any time clamp or ejector pressure equals
or exceeds the respective value during clamp and ejector jogs. A zero
entry inhibits alarm actuation.
Important: High clamp pressure and high ejector pressure alarms (set in
chapter 3), are also active during jog functions.
Worksheet 5ĆA
Initial Clamp and Eject Jog Configuration Values
Control Block
Word
ProĆSet 600 Addr. Value
Description
Units
Clamp, Forward Jog
JGC33
N41:89
Set Output Values Output #1
% Signal Output
2
JGC34
N41:90
Output #2
% Signal Output
2
JGC35
N41:91
Output #3
% Signal Output
2
JGC36
N41:92
Output #4
% Signal Output
2
Clamp, Reverse Jog
JGC41
N41:97
Set Output Values Output #1
% Signal Output
2
JGC42
N41:98
Output #2
% Signal Output
2
JGC43
N41:99
Output #3
% Signal Output
2
JGC44
N41:100
Output #4
% Signal Output
2
Ejector, Advance Jog
JGC49
N41:105
Set Output Values Output #1
% Signal Output
2
JGC50
N41:106
Output #2
% Signal Output
2
JGC51
N41:107
Output #3
% Signal Output
2
JGC52
N41:108
Output #4
% Signal Output
2
Ejector, Retract Jog
JGC57
N41:113
Set Output Values Output #1
% Signal Output
2
JGC58
N41:114
Output #2
% Signal Output
2
JGC59
N41:115
Output #3
% Signal Output
2
JGC60
N41:116
Output #4
% Signal Output
2
Jog Pressure Alarms
JGC07
N41:63
Clamp Jog Pressure Alarm Setpoint
Clamp pressure
1
JGC08
N41:64
Ejector Jog Pressure Alarm Setpoint
Ejector pressure
1
1
Pressure
2
% Signal Output
0000 to 9999 PSI
00.00 to 99.99 %
000.0 to 999.9 Bar
Determine Initial Clamp and
Ejector Jog Values