Select Command and Status Bits

to Sequence Machine Operation

Chapter 6

6-6

Table 6.I

Status Bits for Clamp and Eject Mode

Category:

Bit Status

(when = 1):

QDC Block

Addr.:

ProĆSet

Addr.:

Jog Status

unassigned # 1 jog

SYS01ĆB09

B35/09

unassigned # 2 jog

SYS01ĆB10

B35/10

unassigned # 3 jog

SYS01ĆB11

B35/11

executing clamp forward jog

SYS01ĆB12

B35/12

executing clamp reverse jog

SYS01ĆB13

B35/13

executing ejector advance jog

SYS01ĆB14

B35/14

executing ejector retract jog

SYS01ĆB15

B35/15

Profile Complete

1st clamp close profile complete

SYS02ĆB00

B35/16

2nd clamp close profile complete

SYS02ĆB01

B35/17

3rd clamp close profile complete

SYS02ĆB02

B35/18

LP close profile complete

SYS02ĆB03

B35/19

1st clamp open profile complete

SYS02ĆB10

B35/26

2nd clamp open profile complete

SYS02ĆB11

B35/27

3rd clamp open profile complete

SYS02ĆB12

B35/28

clamp open slow profile complete

SYS02ĆB13

B35/29

ejector profile complete

SYS02ĆB14

B35/30

Busy Status

no action (outputs at zero)

SYS02ĆB15

B35/31

Miscellaneous Status

clamp in mold protection zone

SYS03ĆB00

B35/32

mold safe

SYS03ĆB01

B35/33

tonnage complete

SYS03ĆB02

B35/34

clamp in openĆslow zone

SYS03ĆB06

B35/38

mold open

SYS03ĆB07

B35/39

ejector stopped at end of stroke

SYS03ĆB08

B35/40

mold open dwell timer is timing

SYS03ĆB09

B35/41

ejector forward dwell timer is timing

SYS03ĆB10

B35/42

cycle complete

SYS03ĆB11

B35/43

ejector fully advanced

SYS03ĆB12

B35/44

ejector beyond tip advance position

SYS03ĆB13

B35/45

ejector inside tip retract position

SYS03ĆB14

B35/46

ejector fully retracted

SYS03ĆB15

B35/47