Procedure to determine and record worksheet values, 7ć24 – Rockwell Automation 1771-QDC, D17716.5.87(Passport) CLAMP AND EJECT MODE User Manual
Page 100

Load Initial Configuration Values
Chapter 7
7-24
Follow this procedure to complete each worksheet.
1.
Decide which profiles you will and will not use.
2.
Read the text for the subject parameter.
3.
Determine your initial value for that parameter and add it to each
corresponding worksheet at the listed configuration word address.
Important: Block identifier codes are already recorded for you.
Selected Velocity Control Valve
(FCC02, SCC02, TCC02, FOC02, SOC02, TOC02, OSC02, EAC02, ERC02)
The QDC module is capable of controlling clamp and ejector movement
using a velocity versus position algorithm. Since up to four valves may be
connected to your QDC module, you must inform the QDC module what
valve you want it to control when utilizing this algorithm. Enter the
appropriate values into your configuration worksheets depending on your
valve configuration.
B02
B01
B00
Selects:
0
0
0
Output #1 Used for Velocity Control
0
0
1
Output #2 Used for Velocity Control
0
1
0
Output #3 Used for Velocity Control
0
1
1
Output #4 Used for Velocity Control
Selected Pressure Control Valve
(FCC02, SCC02, TCC02, LPC02, FOC02, SOC02, TOC02, OSC02, EAC02, ERC02)
The QDC module can also control clamp and ejector movement using a
pressure versus position algorithm (This is the only algorithm possible in
the Low Pressure Close profile). Again, you must inform the QDC module
what valve you want it to control when utilizing this algorithm. Enter the
appropriate values into your configuration worksheets depending on your
valve configuration.
B06
B05
B04
Selects:
0
0
0
Output #1 Used for Pressure Control
0
0
1
Output #2 Used for Pressure Control
0
1
0
Output #3 Used for Pressure Control
0
1
1
Output #4 Used for Pressure Control
Procedure to Determine and
Record Worksheet Values
Determine Bit Selections:
Assign Module Outputs for
Your Control Valves