Algorithm
0 = Vel/Pos
1 = Press/Pos
FOC
SOC
TOC
FOC
SOC
TOC
Logical Bridge
0 = Start Next Profile at end
1 = Stop and SetĆOutput
Zone Overrun
0 = Start Clamp Open Slow on Zone Overrun
1 = Stop and Zero Outputs on Zone Overrun
Velocity Units
0 = Percent Velocity
1 = Inches (mm)/Second
OPC Block Identifier
Expert Response Compensation
0 = ON
1 = OFF
bit 15 = Press/Pos OSC
bit 14 = Vel/Pos OSC
bit 13 = Press/Pos TOC
bit 12 = Vel/Pos TCC
bit 11 = Press/Pos SOC
bit 10 = Vel/Pos SOC
Open/Closed Loop Selection
0 = Closed Loop
1 = Open Loop
bit 05 = Press/Pos TOC
bit 04 = Vel/Pos TOC
bit 03 = Press/Pos SOC
bit 02 = Vel/Pos SOC
bit 01 = Press/Pos FOC
bit 00 = Vel/Pos FOC
OSC
Mold Open Dwell Start
0 = Start open dwell timer when mold open
1 = Start open dwell timer when mold open and ejectors done
Code:
Your value
Required initial value
loaded by ProĆSet 600
0 or 1
bit 09 = Press/Pos FOC
bit 08 = Vel/Pos FOC
bit 07 = Press/Pos OSC
bit 06 = Vel/Pos OSC
Load Initial Profile Values for
Machine Tuning
Chapter 8
8-8
The following two pages contain worksheets for the Clamp Open Profile
(one worksheet for bit entries and one for word entries). The valve
spanning procedure in chapter 9 requires specific values in certain block
entries. We have already entered those values for you on your worksheets.
All parameters which require an entry based on your specific machine are
discussed after the worksheet; and in detail in later chapters.
Worksheet 8ĆB
Clamp Open (OPC) Profile Block
Control Word OPC01ĆBxx
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
ProĆSet 600 Addr. B37/bit
591 590 589 588 587 586 585 584 583 582 581 580 579 578 577 576
Value
0
0
0
0
0
0
0
0
0
0
0
1
0
1
0
1
Control Word OPC03ĆBxx
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
ProĆSet 600 Addr. B37/bit
623 622 621 620 619 618 617 616 615 614 613 612 611 610 609 608
Value
0
1
0
0
0
0
0
0
0
1
0
1
0
1
0
1
Control Word OPC04ĆBxx
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
ProĆSet 600 Addr. B37/bit
639 638 637 636 635 634 633 632 631 630 629 628 627 626 625 624
Value
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Determine and Enter Clamp
Open Profile (OPC)