Page 35

Configure the QDC Module's
Inputs and Outputs
Chapter 3
3-2
Command and Status Blocks Used
The following table contains a list of command blocks you are to configure
throughout the course of this chapter. You may reference these command
blocks in sections 1 and 3 of the Plastic Molding Module Reference
Manual (pub. no. 1771-6.5.88).
Block:
Type:
Use in this Chapter:
ProĆSet 600 Files:
Module Configuration (MCC) Command
Configure Module I/O
operating parameters
B35
Module Configuration (MCC) Command
Select Input Ranges for I/O
B35
Module Configuration (MCC) Command
Select Output Ranges for I/O B35
Module Configuration (MCC) Command
Determine Initial Sensor ConĆ
figuration values
N41
Module Configuration (MCC) Command
Determine Software Travel
Limits
N41
Module Configuration (MCC) Command
Enter PressureĆalarm and
TimeĆdelay Setpoints
N41
You select module parameters and I/O ranges by setting configuration bits
in control words. First determine and write down correct settings using
Worksheet 3-A thru Worksheet 3-C as follows:
To Configure:
In Control Word: Starting At
ProĆSet 600 Address:
Use this Worksheet:
Module Parameters
MCC02
B35/528
Worksheet
3-A
Input Range
MCC03
B35/544
Worksheet
3-B
Output Range
MCC04
B35/560
Worksheet
3-C
Select Module Parameters