Blank worksheets appendix a – Rockwell Automation 1771-QDC, D17716.5.87(Passport) CLAMP AND EJECT MODE User Manual
Page 203

Enter Your Initial Values Here
Blank Worksheets
Appendix A
A-3
Worksheet 3ĆD
Determining Initial SensorĆconfiguration Values
Input
Control Word
ProĆSet 600 Addr. Value
Description
Units
1
MCC37
N41:33
Minimum Ejector Position
Ejector Axis Measured from zero
1
MCC38
N41:34
Maximum Ejector Position
Ejector Axis Measured from zero
1
MCC39
N41:35
Analog Signal @ Min Ejector Position
Input Signal Range
2
MCC40
N41:36
Analog Signal @ Max Ejector Position
Input Signal Range
2
2
MCC45
N41:41
Minimum Ejector Pressure
Ejector Pressure
3
MCC46
N41:42
Maximum Ejector Pressure
Ejector Pressure
3
MCC47
N41:43
Analog Signal @ Min Ejector Pressure
Input Signal Range
2
MCC48
N41:44
Analog Signal @ Max Ejector Pressure
Input Signal Range
2
3
MCC23
N41:19
Minimum Clamp Position
Clamp Axis Measured from zero
1
MCC24
N41:20
Maximum Clamp Position
Clamp Axis Measured from zero
1
MCC25
N41:21
Analog Signal @ Min Clamp Position
Input Signal Range
2
MCC26
N41.22
Analog Signal @ Max Clamp Position
Input Signal Range
2
4
MCC31
N41:27
Minimum Clamp Pressure
Clamp Pressure
3
MCC32
N41:28
Maximum Clamp Pressure
Clamp Pressure
3
MCC33
N41:29
Analog Signal @ Min Clamp Pressure
Input Signal Range
2
MCC34
N41:30
Analog Signal @ Max Clamp Pressure
Input Signal Range
2
1
Incremental Distance
2
Input Signal Range
3
Pressure
00.00 to 99.99 Inches
00.00 to 10.00V dc or
0000 to 9999 PSI
000.0 to 999.9 Millimeters
01.00 to 05.00V dc or
000.0 to 999.9 Bar
04.00 to 20.00MADC