Load initial configuration values chapter 7 – Rockwell Automation 1771-QDC, D17716.5.87(Passport) CLAMP AND EJECT MODE User Manual
Page 97

Enter Your Values Here
Load Initial Configuration Values
Chapter 7
7-21
Worksheet 7ĆI (continued)
Ejector Advance (EAC) Configuration Block
Control Word ProĆSet 600 Addr. Value
Description
Units
EAC05
N45:1
1000
Minimum ERC
PercentageĆĆVelocity
Percent
8
EAC06
N45:2
1000
Minimum ERC
PercentageĆĆPressure
Percent
8
EAC08
N45:4
0
Profile Watchdog Timer Preset
Time
1
EAC09
N45:5
*
Output #1 SetĆOutput Value during Advance
Percent Signal Output
4
EAC10
N45:6
*
Output #2 SetĆOutput Value during Advance
Percent Signal Output
4
EAC11
N45:7
*
Output #3 SetĆOutput Value during Advance
Percent Signal Output
4
EAC12
N45:8
*
Output #4 SetĆOutput Value during Advance
Percent Signal Output
4
EAC17
N45:13
0
Output #1 Acceleration Ramp Rate during Advance
Percent Signal Output per Second
5
EAC18
N45:14
0
Output #2 Acceleration Ramp Rate during Advance
Percent Signal Output per Second
5
EAC19
N45:15
0
Output #3 Acceleration Ramp Rate during Advance
Percent Signal Output per Second
5
EAC20
N45:16
0
Output #4 Acceleration Ramp Rate during Advance
Percent Signal Output per Second
5
EAC25
N45:21
0
Output #1 Deceleration Ramp Rate during Advance
Percent Signal Output per Second
5
EAC26
N45:22
0
Output #2 Deceleration Ramp Rate during Advance
Percent Signal Output per Second
5
EAC27
N45:23
0
Output #3 Deceleration Ramp Rate during Advance
Percent Signal Output per Second
5
EAC28
N45:24
0
Output #4 Deceleration Ramp Rate during Advance
Percent Signal Output per Second
5
EAC33
N45:29
*
Output #1 SetĆOutput Value at EndĆof Advance
Percent Signal Output
4
EAC34
N45:30
*
Output #2 SetĆOutput Value at EndĆof Advance
Percent Signal Output
4
EAC35
N45:31
*
Output #3 SetĆOutput Value at EndĆof Advance
Percent Signal Output
4
EAC36
N45:32
*
Output #4 SetĆOutput Value at EndĆof Advance
Percent Signal Output
4
EAC41
N45:37
0
Pressure Minimum Control Limit
Pressure
3
EAC42
N45:38
System Pressure
Pressure Maximum Control Limit
Pressure
3
EAC43
N45:39
*
Selected Pressure Valve Output for Minimum
Percent Signal Output
4
EAC44
N45:40
*
Selected Pressure Valve Output for Maximum
Percent Signal Output
4
EAC45
N45:41
0
Velocity Minimum Control Limit
Velocity along Axis
2
EAC46
N45:42
Max Velocity per
OEM specs*
Velocity Maximum Control Limit
Velocity along Axis
2
EAC47
N45:43
*
Selected Velocity Valve Output for Minimum
Percent Signal Output
4
EAC48
N45:44
*
Selected Velocity Valve Output for Maximum
Percent Signal Output
4
EAC49
N45:45
100
Proportional Gain for Pressure Control
None
EAC50
N45:46
400
Integral Gain for Pressure Control
Inverse Time (Algorithm)
6
EAC51
N45:47
0
Derivative Gain for Pressure Control
Time (Algorithm)
7
Time
1
EAC52
N45:48
200
Proportional Gain for Velocity Control
Inverse Time (Algorithm)
6
EAC53
N45:49
0
Feed Forward Gain for Velocity Control
None
EAC57
N45:53
0
Profile High Pressure Alarm Setpoint
Pressure
3
1
Time
2
Velocity along Axis
3
Pressure
4
Percent Signal Output
00.00 to 99.99 Seconds 00.00 to 99.99 Inches per Second 0000 to 9999 PSI 00.00 to 99.99
000.0 to 999.9 Millimeters per Sec 000.0 to 999.9 Bar
5
Percent Signal Output per Second
6
Inverse Time (Algorithm)
7
Time (Algorithm)
8
Percent
0000 to 9999 00.00 to 99.99 Minutes 00.00 to 99.99 Minutes 00.00 to 99.99
00.00 to 99.99 Seconds
*Refer to the appropriate section later in this chapter for information on this parameter