beautypg.com

Rockwell Automation 1771-QDC, D17716.5.87(Passport) CLAMP AND EJECT MODE User Manual

Page 82

background image

Velocity Control Valve

Pressure Control Valve

Pressure Algorithm Selection

SCC Block Identifier

000 = Output 1

001 = Output 2

010 = Output 3

011 = Output 4

000 = Output 1

001 = Output 2

010 = Output 3

011 = Output 4

0 = Dependent Gains

1 = Independent Gains

Code:

Your value

Required initial value

loaded by ProĆSet 600

0 or 1

Load Initial Configuration Values

Chapter 7

7-6

Worksheet 7ĆB

Second Clamp Close (SCC) Configuration Block

Control Word SCC01ĆBxx

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00

ProĆSet 600 Addr. B37/bit

79

78

77

76

75

74

73

72

71

70

69

68

67

66

65

64

Value

0

0

0

0

0

0

0

0

0

0

0

0

0

1

0

0

Control Word SCC02ĆBxx

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00

ProĆSet 600 Addr. B37/bit

95

94

93

92

91

90

89

88

87

86

85

84

83

82

81

80

Value

0

0

0

0

0

0

0

0

1

0