Complete your sensor configuration, 3ć11 – Rockwell Automation 1771-QDC, D17716.5.87(Passport) CLAMP AND EJECT MODE User Manual
Page 44
Enter Your Final SensorĆconfiguration Values Here
Configure the QDC Module's
Inputs and Outputs
Chapter 3
3-11
Complete the procedure for configuring the QDC module to match its
sensors by spanning them over their intended range with the machine in
operation. Here we describe how you determine:
clamp position sensor values
ejector position sensor values
clamp pressure sensor values
ejector pressure sensor values
In the procedures that follow, measure and record:
minimum and maximum positions
corresponding signal values
minimum and maximum pressures
corresponding signal values
After determining these values, write them down on Worksheet 3-E.
Important: You must complete this configuration before proceeding to
any other chapters on module configuration.
Worksheet 3ĆE
Final SensorĆconfiguration Values
Input
Control Word ProĆSet 600 Addr.
Value
Description
Units
1
MCC37
N41:33
0
Minimum Ejector Position
Ejector Axis Measured from zero
1
MCC38
N41:34
Maximum Ejector Position
Ejector Axis Measured from zero
1
MCC39
N41:35
Analog Signal @ Min Ejector Position
Input Signal Range
2
MCC40
N41:36
Analog Signal @ Max Ejector Position
Input Signal Range
2
2
MCC45
N41:41
0
Minimum Ejector Pressure
Ejector Pressure
3
MCC46
N41:42
Maximum Ejector Pressure
Ejector Pressure
3
MCC47
N41:43
Analog Signal @ Min Ejector Pressure
Input Signal Range
2
MCC48
N41:44
Analog Signal @ Max Ejector Pressure
Input Signal Range
2
3
MCC23
N41:19
0
Minimum Clamp Position
Clamp Axis Measured from zero
1
MCC24
N41:20
Maximum Clamp Position
Clamp Axis Measured from zero
1
MCC25
N41:21
Analog Signal @ Min Clamp Position
Input Signal Range
2
MCC26
N41:22
Analog Signal @ Max Clamp Position
Input Signal Range
2
4
MCC31
N41:27
0
Minimum Clamp Pressure
Clamp Pressure
3
MCC32
N41:28
Maximum Clamp Pressure
Clamp Pressure
3
MCC33
N41:29
Analog Signal @ Min Clamp Pressure
Input Signal Range
2
MCC34
N41:30
Analog Signal @ Max Clamp Pressure
Input Signal Range
2
1
Incremental Distance
2
Input Signal Range
3
Pressure
00.00 to 99.99 Inches
00.00 to 10.00V dc or
0000 to 9999 PSI
000.0 to 999.9 Millimeters
01.00 to 05.00V dc or
000.0 to 999.9 Bar
04.00 to 20.00MADC
Complete your Sensor
Configuration