Rockwell Automation 1771-QDC, D17716.5.87(Passport) CLAMP AND EJECT MODE User Manual
Page 70

Select Command and Status Bits
to Sequence Machine Operation
Chapter 6
6-3
Table 6.C
Command Bits for Automatic Functions in Clamp and Eject Mode
To initiate this
profile/movement:
Toggle this bit: Or the profile/movement
starts automatically after:
If this bit is
Reset:
1st Clamp Close
DYC02ĆB00
-
-
2nd Clamp Close
DYC02ĆB01
1st Clamp Close
CPC03ĆB08
3rd Clamp Close
DYC02ĆB02
2nd Clamp Close
CPC03ĆB09
Low Pressure Close DYC02ĆB03
3rd Clamp Close
CPC03ĆB10
1st Clamp Open
DYC02ĆB10
-
-
2nd Clamp Open
DYC02ĆB11
1st Clamp Open
OPC03ĆB08
3rd Clamp Open
DYC02ĆB12
2nd Clamp Open
OPC03ĆB09
Clamp Open Slow
DYC02ĆB13
3rd Clamp Open
OPC03ĆB10
First Ejector
Advance
DYC02ĆB14
On Clamp Position During
Open
EPC03ĆB08 and
EPC03ĆB09
Ejector Continue
DYC03ĆB15
Previous Ejector Stroke
EPC03ĆB12
Table 6.D
Status and Command Bit Interaction for Automatic Functions
in Clamp and Eject Mode
For this
Profile/Movement:
During Execution
this bit is:
At Completion
this bit is:
At completion
If this
Then this
command bit is:
status bit is:
SET
RESET
SET
RESET
also SET
also SET
1st Clamp Close
SYS21ĆB00 SYS02ĆB00 SYS02ĆB00 SYS21ĆB00 CPC03ĆB08
SYS22ĆB00
2nd Clamp Close
SYS21ĆB01 SYS02ĆB01 SYS02ĆB01 SYS21ĆB01 CPC03ĆB09
SYS22ĆB01
3rd Clamp Close
SYS21ĆB02 SYS02ĆB02 SYS02ĆB02 SYS21ĆB02 CPC03ĆB10
SYS22ĆB02
Low Pressure Close SYS21ĆB03 SYS02ĆB03 SYS02ĆB03 SYS21ĆB03 ---
SYS22ĆB03
1st Clamp Open
SYS21ĆB10 SYS02ĆB10 SYS02ĆB10 SYS21ĆB10 OPC03ĆB08
SYS22ĆB10
2nd Clamp Open
SYS21ĆB11 SYS02ĆB11 SYS02ĆB11 SYS21ĆB11 OPC03ĆB09
SYS22ĆB11
3rd Clamp Open
SYS21ĆB12 SYS02ĆB12 SYS02ĆB12 SYS21ĆB12 OPC03ĆB10
SYS22ĆB12
Clamp Open Slow
SYS21ĆB13 SYS02ĆB13 SYS02ĆB13 SYS21ĆB13 ---
SYS22ĆB13
Ejector Advance
SYS21ĆB14 SYS02ĆB14 SYS21ĆB14 SYS02ĆB14 EPC03ĆB12
SYS22ĆB14
Intermediate Ejector
Retract
SYS21ĆB14 SYS02ĆB14 SYS21ĆB14 SYS02ĆB14 EPC03ĆB12
SYS22ĆB15
Final Ejector Retract SYS21ĆB14 SYS02ĆB14 SYS02ĆB14 SYS21ĆB14 ---