Chapter 7

Using Multi-Drive Mode

5.

In the Module Definition window, edit the following information for the
master drive:

On the Module Definition window, notice that the automatically-assigned
controller tags Drive Status, Feedback, Logic Command, and Reference
are always used.

TIP

You may create a database from a network accessible drive using the
Create Database... button (Recommended).

Box

Setting

Drive Rating

The voltage and current rating of the drive. If the drive rating is not listed, the drive
database is not installed on your computer. To get the drive rating, use the Create
Database…
, or Web Update… button described above.

Revision

The major and minor revision of the firmware (database) in the drive. If the drive’s major
and minor revision is not available, the drive database is not installed on your computer. To
get the correct database revision, use one of the following buttons at the bottom left of the
Module Definition window:
• Create Database… Creates a database from an online network multi-drive. Clicking

this button displays an RSLinx RSWho window. Browse to the online drive (PowerFlex
525), select it, and click OK. The database will be uploaded and stored on the computer.
Thereafter, close the Module Definition window and then re-open it to display the new
revision.

• Web Update… When a drive is not available online, opens the Allen-Bradley Drives

Web Updates web site to download a specific database file. After downloading the file,
close the Module Definition window and then re-open it to display the new revision.

Electronic Keying Compatible Module. The “Compatible Module” setting for Electronic Keying ensures the

physical module is consistent with the software configuration before the controller and
bridge make a connection. Therefore, ensure that you have set the correct revision in this
window. See the online Help for additional information on this and other Electronic Keying
settings. If keying is not required, select “Disable Keying.” Drives do not require keying, and
so “Disable Keying” is recommended.

IMPORTANT

The Velocity/Positioning mode select is in the lower right of the
window when the master PowerFlex 525 drive is selected.