beautypg.com

Rockwell Automation 25B PowerFlex 525 Embedded EtherNet/IP Adapter User Manual

Page 113

background image

Rockwell Automation Publication 520COM-UM001B-EN-E - March 2013

113

Troubleshooting

Chapter 8

F687
F688
F689
F690
F691
F692

HW Addr 1
HW Addr 2
HW Addr 3
HW Addr 4
HW Addr 5
HW Addr 6

Decimal value of each byte in the adapter’s Ethernet hardware address.

F693
F694
F695
F696

EN IP Addr Act 1
EN IP Addr Act 2
EN IP Addr Act 3
EN IP Addr Act 4

Value of each byte in the adapter’s present IP address. A value of “0” appears if the
adapter does not currently have an IP address.

F697
F698
F699
F700

EN Subnet Act 1
EN Subnet Act 2
EN Subnet Act 3
EN Subnet Act 4

Value of each byte in the adapter’s present subnet mask. A value of “0” appears if the
adapter does not currently have a subnet mask.

F701
F702
F703
F704

EN Gateway Act 1
EN Gateway Act 2
EN Gateway Act 3
EN Gateway Act 4

Value of each byte in the adapter’s present gateway address. A value of “0” appears if the
adapter does not currently have a gateway address.

F705
F709
F713
F717
F721

Drv 0 Logic Cmd
Drv 1 Logic Cmd
Drv 2 Logic Cmd
Drv 3 Logic Cmd
Drv 4 Logic Cmd

In Multi-drive mode, this is the logic command being transmitted to drive 0.
In Single-drive mode, this is the logic command being used by the drive (whether HS-
DSI, EtherNet/IP, or DSI) at the time. If comms control is NOT being used, and the drive is
in single-drive mode, then this parameter will show 0.

F706
F710
F714
F718
F722

Drv 0 Reference
Drv 1 Reference
Drv 2 Reference
Drv 3 Reference
Drv 4 Reference

In Multi-drive mode, this is the reference being transmitted to drive 0.
In Single-drive mode, this is the reference being used by the drive (whether HS-DSI,
EtherNet/IP, or DSI) at the time. If comms control is NOT being used, and the drive is in
Single-drive mode, then this parameter will show 0.

F707
F711
F715
F719
F723

Drv 0 Logic Sts
Drv 1 Logic Sts
Drv 2 Logic Sts
Drv 3 Logic Sts
Drv 4 Logic Sts

In Multi-drive mode, this is the logic status being received from drive 0.
In Single-drive mode, this is the logic status of the drive at the time.

Embedded EtherNet/IP Adapter Diagnostic Parameters

No.

Name

Description

255.255.255.255.255.255

[HW Addr 1]

[HW Addr 2]

[HW Addr 3]

[HW Addr 4]

[HW Addr 5]

[HW Addr 6]

255.255.255.255

[EN IP Addr Act 1]

[EN IP Addr Act 2]

[EN IP Addr Act 3]

[EN IP Addr Act 4]

255.255.255.255

[EN Subnet Act 1]

[EN Subnet Act 2]

[EN Subnet Act 3]

[EN Subnet Act 4]

255.255.255.255

[EN Gateway Act 1]

[EN Gateway Act 2]

[EN Gateway Act 3]

[EN Gateway Act 4]