beautypg.com

100ahex: manufacturer’s software version, 100chex: guard time, 100dhex: life time factor – Lenze EMF2175IB User Manual

Page 60: 1010hex: store parameters, Canopen, 6parameter setting, 7 100a, Manufacturer’s software version, 8 100c, Guard time

background image

CANopen

6

Parameter setting

6-32

L

BA2175 EN 2.0

6.4.1.7

100A

hex

: Manufacturer’s software version

Controller and module software version

Index [hex] Subindex

Name

Data type

Authorisation

100A

0

Manufacturer software version Vis. string

{11 characters}

const

6.4.1.8

100C

hex

: Guard time

Monitoring time

Index [hex] Subindex

Name

Data type

Authorisation

100C

0

Guard time

U16

rw

The guard time is indicated in [ms].

If guarding is not to be supported, the default setting of 0 should not be changed.

6.4.1.9

100D

hex

: Life time factor

Index [hex] Subindex [hex]

Name

Data type

Authorisation

100D

0

Life time factor

U8

rw

If the guarding function, which results from guard time and life time factor, is not to be supported,
the default setting of 0 should not be changed. For further information see chapter 6.1.2.1.

6.4.1.10

1010

hex

: Store parameters

Parameter storage in the EEPROM.

Index [hex] Subindex

Name

Data type

Authorisation

1010

0

Store parameters

U32

ro/rw

1010

1 ... 3*

Store parameters

U32

ro/rw

The subindexes 1, 2 and 3 are presently not supported.

Parameter storage

Error messages occur when

storage is incorrect (in bytes 5 ...8): 0606 0000

hex

the signature is wrong: 0800 0020

hex

Tip!

For module parameter storing, the signature “ save” must be in the telegram data.

Assignment of telegram data words for parameter storing

Signature

MSB

LSB

ISO 8859 (ASCII)

e

v

a

s

hex

65

76

61

73

Bit assignment for reading right

U32

0

1

2 - 31

0/1

0/1

0

0

0

..

0

0

0