6

Parameter setting

6-18

L

BA2175 EN 2.0

6.3.4

Process-data assignment for 8200 vector

A change of code L-C0001 to 3 starts the preconfiguration of process data words in the controller
(see chapter 6.3.1). .

Tip!

Frequency and speed values are normalised with

24000

≡ 

480 Hz.

Process data telegram to drive

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

Control word

Low byte

Control word

High byte

AIF-IN.W1

Low byte

AIF-IN.W1

High byte

AIF-IN.W2

Low byte

AIF-IN.W2

High byte

xx

xx

Control word: see chapter 6.3.4.1.

AIF-IN.Wx is parameterised under code L-C0412.

AIF

AIF-IN

AIF-CTRL

AIF-IN.W2

AIF-IN.W1

.B15

.B12

.B0

.B1

.B2

.B3

.B4

...

...

...

...

...

...

...

...

...

...

...

...

.B8

.B9

.B10

.B11

DCTRL

QSP

CINH

TRIP-SET

TRIP-RESET

DCTRL

16 bit

16 bit

16 bit

2141LON011

L-C0410/x = 10
L-C0410/x = 11
L-C0410/x = 12

...

...

...

L-C0410/x = 22

L-C0410/x = 25

...

...

...

...

...

...

...

...

L-C0412/x = 10

L-C0412/x = 11

...

Fig. 6-5

Function block AIF-IN in 8200 vector (freely programmable assignment, for default setting see (

^

6-20) )

Note:
A subcode (“ x” in figure) determines the bit or word meaning (see 8200 vector Operating Instructions)