beautypg.com

3 general data and application conditions, 4 rated data, 5 dimensions – Lenze EMF2175IB User Manual

Page 14: Canopen, 3technical data

background image

CANopen

3

Technical data

3-2

L

BA2175 EN 2.0

3.3

General data and application conditions

For

Values

Order name

33.2175IB

Communication media

DIN ISO 11898

Baud rate [kbit/s]

10

20

50

125

250

500

1000

Maximum cable length [m]

5000

2500

1000

550

250

100

25

Ambient temperature

during operation:

-20 °C

to

60 °C

Ambient temperature

during transport:

-25 °C

to

70 °C

during storage

-25 °C

to

60 °C

Permissible humidity

Class 3K3 to EN 50178 (without condensation, average relative humidity 85%)

24-V-DC-
Voltage supply

external supply only: 820X

internal or external supply: 9300 servo PLC / 93XX / 821X / 822X / 8200 vector (see chapter 4.3.2)

3.4

Rated data

For

Values

Voltage supply

24 V DC

ñ 10 %; max. 100 mA

Communication medium ISO 11898

Rated insulation voltage

Type of insulation

PE

50VAC

Electrical isolation

External supply (term. 39/59)

-

No electrical isolation

Power stage

– 820X / 821X

270 V AC

Basic insulation

– 822X / 8200 vector

270 V AC

Double insulation

Ins lation oltages for

– 93XX

270 V AC

Double insulation

Insulation voltages for
bus systems

Control terminals:

bus systems

– 820X / 8200 vector

(with internal supply)

-

No electrical isolation

– 8200 vector

(with external supply)

100 V AC

Basic insulation

– 821X

50 V AC

Electrical isolation

– 822X

270 V AC

Basic insulation

– 93XX

270 V AC

Basic insulation

External bus systems

0 V AC

No electrical isolation

Pollution degree

VDE0110, part 2, pollution degree 2

3.5

Dimensions

75

62

36

18

DeviceNet
CANopen

Fig. 3-1

Dimensions: 2175 fieldbus module (all dimensions in mm)

Show/Hide Bookmarks