Setting Intrusion Detection
The Limited and Secure security modes let you determine how the
switch responds when it receives MAC addresses in excess of its
threshold.
1. Perform the procedure Configuring Port Security on page 62.
2. Type D to select Set Intrusion Detection.
The following prompt is displayed:
Set intrusion detection status->Enter port number >
Port number is in range of 1 to 50
3. Enter the number of the port to configure. Press Enter.
The Intrusion Detection Status Menu is displayed in Figure 17
Figure 17 Intrusion Detection Status Menu
4. Type the number associated with the desired setting for Intrusion
Detection Status. The following parameters are available:
1 - No action
2 - Disable the port only
3 - Notify with trap only
4 - Notify with trap and disable the port
A change to detection status is immediately activated on the port.
AT-8350GB Local Management System
Advanced Switch Configuration -> Intrusion Detection Status Menu
Item Description
------ -------------------------------------
1
No action
2
Disable the port only
3
Notify with trap only
4
Notify with trap and disable the port
Set intrusion detection status->Enter item number >
Select item number for intrusion detection status