AT-S41 User’s Guide

182

Good Multicast
Number of valid multicast packets received on the port.

CRC/Align Errors
Number of packets with a cyclic redundancy check (CRC) error but
with the proper length (64-1518 bytes) received on the port.

Undersize Packets
Number of packets that were less than the minimum length
specified by IEEE 802.3 (64 bytes including the CRC) received on
the port.

Oversize Packets
Number of packets exceeding the maximum specified by IEEE
802.3 (1518 bytes including the CRC) received on the port.

Fragments
Number of undersized packets, packets with alignment errors,
and packets with FCS errors (CRC errors) received on the port.

Jabbers
Number of electrical signal errors detected on the port.

Collisions
Number of packet collisions on the port.

64-Byte Pkts
Number of 64-byte packets sent or received by the port. The
minimum length of an Ethernet packet is 64 bytes.

65-127 Pkts
Number of 65- to 127-byte packets sent or received by the port.

128-255 Pkts
The number of 128- to 255-byte packets sent or received by the
port.

256-511 Pkts
Number of 256- to 511-byte packets sent or received by the port.

512-1023 Pkts
Number of 512- to 1023-byte packets sent or received by the port.

1023-1518 Pkts
Number of 1023- to 1518-byte packets sent or received by the
port. The maximum length of an Ethernet packet is 1518 bytes.