Adding static mac addresses – Allied Telesis AT-S41 User Manual
Page 115

AT-S41 User’s Guide
115
Adding Static MAC Addresses
The management software allows you to assign up to 256 static MAC
addresses on an AT-8350GB Fast Ethernet switch.
To add a static address to the MAC address table, perform the following
procedure:
1. From the Main Menu, type B to select Basic Switch Configuration.
2. From the Basic Switch Configuration Menu, type F to select
Forwarding Database.
3. From the Forwarding Database Menu, type S to select Static Address
Table.
4. From the Static Address Table Menu, type A to Add New Entry.
The following prompt is displayed:
Enter MAC Address(xx:xx:xx:xx:xx:xx) >
5. Enter the static MAC address in the following format:
xx:xx:xx:xx:xx:xx
Once you have specified the MAC address, the following prompt
is displayed:
Add new entry->Enter Stack ID >
Stack ID is in range of 1 to X
X equals the Stack ID of the last switch in your switch stack.
6. Enter the Stack ID of the switch for the port you want to assign a static
MAC address.
Once you have entered the Stack ID, the following prompt is
displayed:
Add new entry->Enter port number >
Port number is in range of 1 to 50
7. Enter the port number you want to assign a static MAC address.
Once you have specified the port number, the following prompt
is displayed:
Add new entry->Enter VLAN ID>
VLAN ID is in range of 1 to 4094
8. Enter the VLAN ID of the VLAN the port belongs to.
Once you have specified the VLAN ID, the management software
adds the static address to the MAC address table.
9. Repeat steps 4 through 8 to enter additional static MAC addresses.