Red Lion IndustrialPr 6000 Router User Manual
Page 79

Software User Guide
79
Network Tab
Coordinate with Dial‐up PPP: You may select specific actions to be performed either upon PPP connect, PPP discon‐
nect or both.
Do Nothing: Perform no action
Restart: IPSEC is restarted
Stop: IPSEC is stopped
With these combinations, the connection management may be fine tuned so that the tunnel(s) may be able to restart
faster rather than having to rely on Dead Peer detection or other time out mechanisms alone.
IPSEC Tunnels
•
Click on the Add button and the following General Settings dialog window will appear:
Tunnel Name (Required): Enter some descriptive text in this field as an aid identifying it. The value must not contain
spaces.
Enable Tunnel: Specify whether this tunnel should connect to its remote peer now and after any reboot.