QUICK START GUIDE

IndustrialPro

TM

Series Router

GSM, CDMA, HSPA and LTE

UNPACKING INSTRUCTIONS

1

Unpack the Red Lion unit and verify the following
components are enclosed for the

IndustrialPro

TM

Router

(Figure A).

Figure A: Package Contents SN/RAM-6XXX:

2

Contact your cellular provider (carrier) and request a data
account. For CDMA models (

SN/RAM

-66XX), give the ESN

number of the router to the carrier to activate the data
account. For GSM, HSPA and LTE models (

SN/RAM

-64XX,

SN/RAM

-68XX & SN/RAM-67xx) the carrier should provide

you with a SIM card to insert into the router, along with the
APN, username, & password for data connectivity.

3

Insert the SIM card (GSM, HSPA and LTE models only):

Locate the SIM slot on the right side of the modem

Insert the card with its cut side facing forward and on the
left.

Using the tip of a pen, push it in until it clicks.

4

An antenna with an SMA connector should be connected to
the router. This antenna should meet the specifications
listed below. Also see Hardware Guide for more information
on antennas.

3G: Dual-band 800 & 1900 MHz

LTE: 700MHz

Nominal 50 ohm impedance

Voltage Standing Wave Ratio (VSWR) less than 2.5:1

5

There are 4 methods to provide power to the router:

4-pin Molex connector

– available on SN-6X00

4-pin screw terminal

– available on SN-6XX1/EB

Side mounted 2.5mm barrel connector

– all models

Power-over-Ethernet

– available on SN-6X01EB

The modem requires a power source between 8 and 30
VDC to operate:

Label

Color

Description

GND

Black

Ground

PWR+

Red

Power 8 to 30 VDC (500mA@12VDC)

IN

White

Future feature

– not supported

OUT

Green

Future feature

– not supported

6

Please allow 2-4 minutes for the unit to recognize the
cellular data card and connect to the cellular network. When
this has occurred the Signal Strength LEDs should light up
(see table on back). If signal strength is not lit or flashes
slowly, please refer to the User Manual at

www.sixnet.com

.

7

Connect to the Ethernet RJ45 port for network connectivity.

ACCESSSING THE GRAPHICAL USER INTERFACE (GUI)

1

Connect PC to the IndustrialPro

TM

Router

Connect a CAT-5 Ethernet cable between the local PC and
the unit’s Ethernet port. Verify the link LED is lit.

2

Setup PC IP Address

For assistance with configuring your PC, see the appropriate
Microsoft Windows support webpage listed at:

http://support.microsoft.com

.

PC to Ethernet Interfaces
Select “Use the following IP address” and fill in the blank
fields with the information below:

Ethernet 0

IP address

192.168.0.2

Subnet mask

255.255.255.0

Default gateway

192.168.0.1

Preferred DNS

192.168.0.1

3

Access Graphical User Interface

Open a web browser & enter the following in the
address bar:

http://192.168.0.1:10000/

LOGIN INSTRUCTIONS

• For User Name enter:

admin (lowercase letters)

• For Password enter:

last six digits of the unit serial number (lowercase)

Upon successfully logging in you will see the following screen

.

Figure B: GUI

You are now connected to the Management GUI. If you should
see anything other than the GUI screen shown, please refer
to the Software User Guide located at:

www.sixnet.com

.

SN-/RAM 6X00 AC adapter with
either barrel connector (AC) or Molex
(MX), or 15ft Molex cable (DC) can be
ordered in a kit (ie. SN -6600-XX-AC,
-DC, or

–MX) or ordered separately.

(SN -6400 not available).

SN/RAM-6X01-4: pin plug with screw
terminals to connect to an external
DC power source. Available with AC
adapter with barrel connector (AC).

SN/RAM-6X21-4: pin plug with screw
terminals to connect to an external
DC power source. Available with AC
adapter with barrel connector (AC).

Antennas sold separately