beautypg.com

Red Lion Converter Modules User Manual

Converter modules, Vcm - voltage converter modules, Specifications

background image

VCM - VOLTAGE CONVERTER MODULES

Converts AC/DC voltages to an acceptable signal input for many RLC counters
and accessories and provides input/output voltage isolation.

TCM - TRIAC CONVERTER MODULE

Accepts unloaded, high off-state leakage triac output from sensors and
programmable controllers.

LCM - LOGIC CONVERTER MODULE

Interfaces with CMOS, TTL, and other logic circuits up to +28 VDC, at speeds to
50 KHz. Allows Cub Counters to share sensor outputs with other series counters.

These miniature sized modules are completely encapsulated in PVC, which

provides protection against oil, water, dirt, and mechanical damage. They can be
quickly and easily mounted to most surfaces by using the self-stick adhesive pad.

VCM - VOLTAGE CONVERTER MODULES

These modules provide a convenient way to adapt RLC Counters to most any

machine control voltage signal. They also make it easy to upgrade electro-
mechanical counter installations with RLC Counters.

VCM’s are available in two input voltage ranges that cover the spectrum

from 4-270 V. The non-polarized input of these modules will accept A.C. (50/60
Hz)
or D.C. voltages at input cycles up to 30 Hz. The output uses MOSFET
technology that is compatible with either the L.S. Count or Remote Reset inputs
of RLC Counters. Electrical isolation between input and output is achieved by
means of an internal opto-isolator rated at 2300 V

RMS

.

SPECIFICATIONS

1. INPUT: VCM1 = 4 to 50 VAC/DC, 50/60 Hz

VCM2 = 50 to 270 VAC/DC, 50/60 Hz

2. OUTPUT: Solid state DC contact closure

Output rating: 30 VDC at 100 mA max
Output Isolation: 2300 V

RMS

Off State Leakage: 1

A max

3. FREQUENCY: Max output frequency 20 Hz
4. ENVIRONMENT: 0-50 ºC

CONVERTER MODULES

ADAPTS MANY RED LION CONTROLS’ COUNTERS AND ACCESSORIES

TO A WIDE RANGE OF SIGNAL SOURCES

Bulletin No. VCM-A
Drawing No. LP0646
Released 02/10

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

1

(SEE ORDERING INFORMATION
FOR WIRE COLOR)

BLACK

OUTPUT LEADS: 6" (150mm) Long
22GA Stranded, 300V Insulation

INPUT LEADS: 6"(150mm) Long, 22GA. VCM
and TCM Leads have 600V Insulation. LCM has
3 Leads with 300V Insulation. (For color codes
see specific model.)

1.12 (28.5)

1.52 (38.5)

0.71
(18)

0.45

(11.5)

SELF STICK

ADHESIVE PAD

OUTPUT

INPUT

DIMENSIONS FOR VCM, TCM, & LCM In inches (mm)