Software User Guide

56

Network Tab

Click on the “Save” button for changes to be saved without activating the interface, the “Apply” button will save 
your settings and apply them immediately. To revert to the previous defaults, click on the “Revert” button.

3.4.2.3

Switch Control

The purpose of the Switch Control function is to create a WAN/LAN separation This gives the user the ability to create a 
divided network with additional capabilities. This option only applies to units with the 5 port unmanaged switch (6x21).

Switch Control Settings

Enable Split Lan: This will alter the switch port allocations. When disabled, all switch ports 1‐5 will be treated as a sin‐
gle LAN. This will be configurable as eth0 and will default to being a firewall trusted/internal interface.

When enabled, port 5 will be divided out as a WAN port, eth0 (firewalled as external/untrusted). Ports 1‐4 will be an inter‐
nally trusted LAN (eth1). 

Warning:

When switching modes, your firewall interface tables will be rebuilt and may need any custom changes reapplied. In 
addition, a USER INITIATED reboot is required to complete the mode switch.

Warning:

When enabling switch mode, current ethernet settings (eth0) will apply only to the single WAN port. On the front of 
the unit, this may be shown as  under the power connector. The remaining four ports will be configured as a 
LAN (eth1).

Please check your Ethernet connections to make sure that the new settings will not conflict with previous network config‐
urations. You may need to revisit your Untrusted/Trusted interface lists in the Firewall ‐> General Settings, as these will 
revert to new defaults (eth0 will be firewalled as Untrusted!). After Apply is clicked and you check firewall/ethernet config‐
urations, a reboot is required to complete this process.