iMac G5 (20-inch) Repair Extension Program -

8

4.

Affected capacitors will have a “+” sign stamped into the top of the capacitor.

Note:

Not all capacitors stamped with a “+” sign are faulty, so further inspection is required to

determine whether one or more of the capacitors are faulty.

5.

Failed capacitors will no longer have a flat top and can be identified by signs of bulging

(shown below) and/or venting. The top may bulge upward. In severe cases the top of

the capacitor may show signs of electrolyte venting which appears as a small amount

of cream-colored paste around the top of the capacitor. One or both of these

symptoms indicates that the capacitor has or will likely fail.

Warning:

Use caution

when handling failed electronic components, and be sure to wash your hands

afterwards.