90

Horizontal Scale Setting

Set horizontal axis (Voltage)

Background

The X (horizontal) axis is selectable from Voltage
and Frequency sweep.

When Voltage sweep is selected: measurement
Frequency is fixed

When Frequency sweep is selected:
measurement Voltage is fixed

Select Drive level
(Voltage)

1. Press the Up/Down key and move

the cursor to Sweep.

Sweep:

Frequency

2. If necessary, press the Left/Right

key to change the sweep setting to
Voltage (Drive Level).

Frequency

Drive Level

Set start Voltage

3. Press the Up/Down key and move

the cursor to Start.

Start:

:

50mV

Use the numerical keys to enter the
starting Voltage.

Range

10mV ~ 2V (AC≤3 MHz)
10mV ~ 1V (AC>3 MHz) *1mV step

100mV

m

V/A

Enter

1V

V/A

Enter

Backspace

All clear

Clear

If a wrong unit is entered, the value is cancelled.