Conventional Fieldwork

77

f. The Stake Points screen will show the necessary

FORWARD / BACK and Go RIGHT / Go LEFT
information that the rod man must move in order

to be located over the design point. In this
example, the Go RIGHT value indicates 0, which

means the rod is precisely on the line between
the total station and the design point. The BACK
value indicates 0.711, which indicates that the
rod must move back (away from the total station)
0.711 feet to be over the design point. The Fill
value is zero so no dirt needs to be cut or filled at

the rod location to match the design elevation.

g. Assuming the rod has been repositioned, take

another shot by tapping the Shot

.

button and

enter the following new shot data:

Angle Right: 45
Zenith Angle: 90

Slope Dist: 70.8 and then tap to continue.

h. The rod must now move FORWARD by 0.089 feet

to be over the design point. We will assume that

this is close enough and will store the point from
this shot by tapping the Store… button.

i. Enter the following point information:

Point: 5
Description: Staked and tap . This will return
you to the first Point Stake screen.