Field procedure, Enable post processing, Start recording in receiver – Spectra Precision Survey Pro v4.6 Recon and Nomad User Manual User Manual
Page 318: Static data collection
User’s Manual – GPS Mode
308
Field Procedure
Enable Post Processing
1. Create a post processing receiver profile (Page 222).
Note: For simultaneous RTK and post processing data collection,
receiver recording will be started automatically when you configure
the RTK base and rover and specify a post processing recording
interval. If you wish to do post processing only data collection, you
need to complete the next step as well.
Start Recording in Receiver
2. Go to the Survey > Post Processing screen. You will be prompted
to choose a receiver from the available post processing receivers.
Tap Connect and the Post Processing screen will open.
Note: If you are currently connected to the RTK base or rover
receiver, you will not be allowed to enter the Post Processing screen.
If you tap Post Processing when connected to the RTK base or rover,
Survey Pro will check the receiver to see if it is currently logging
data. If it is, you will be prompted if you wish to stop data logging on
this receiver. If the receiver is not logging data, you will be prompted
if you wish to clear the RTK setup so you can set this receiver as a
post processing only receiver.
3. Select the desired Recording Interval.
4. Choose Start Static if you want to configure a receiver to record
raw data at a stationary setup. Choose Start Stop/Go if you want
to configure a receiver to do stop and go data collection.
Static Data Collection
1. Choose if you wish to store point in: Receiver and job file or the
Receiver file only
. If you choose to store the point in Receiver and
job file,
then the Point must be a unique point name in the Survey
Pro job and you will be prompted to put the point on the