GPS Module

305

Note: For continuous data collection (except Manual: multi
descriptions

), once the first point is accepted, all additional points will

be stored with the same description, layer, and attributes. When

using Manual: multi descriptions mode, you will be prompted for
description, layer, and attributes (if set) after every point.

4. Tap Feature. On the Feature Collection screen, select a Method.

An explanation of the selected method is displayed at the bottom

of the screen. See the Reference Manual for more information.

5. If you select a continuous method, or the Hold Still method, you

must specify an appropriate Interval.

6. Tap Start to begin measurements. The Occupy Data Points screen

displays the local coordinate.

7. When you are ready to begin continuous collection, tap Topo SS.

8. If you are using a continuous interval, Accept disappears and

points are stored when the interval is exceeded.

9. If your mode is Manual, tap Accept when you want to collect a

point. If your mode is Manual: multi descriptions, you will be
prompted for a description, layer, and attributes (if set) for each

point.

10. If you want to see a list of points stored so far, tap View Points.

11. If you wish to store points at any time during your continuous

interval, tap Topo SS.

12. Tap Done to end feature collection and return to the Data

Collection screen.

Note: When doing continuous data collection, if your interval is

exceeded, but your acceptance criteria or RMS criteria are not met,

then you will be prompted to Accept the point anyway or to Wait for
the measurement to pass. If you choose to Wait, and then Cancel, you
will be prompted to Accept the point anyway or to Exit.