User’s Manual – GPS Mode

296

The following conditions must be met in order to use the Remote

Elevation routine.

• The base and rover must be set.
• You must be using a geoid model as part of your vertical

coordinate system.

• The horizontal coordinate system must be solved.

1. Open the Survey > Remote Elevation screen.
2. If your benchmark is not in the job file, select the Add Benchmark

checkbox, enter the Elevation, and specify a new point number in

the New Point field.

Note: You cannot enter a new elevation for an existing point using the
Remote Elevation routine.

3. If your benchmark is a point in the job file, enter the point name.
4. Occupy the benchmark with the rover and tap

Occupy Benchmark to access the Occupy Control Point screen and

begin measurements to the point.

5. When you are satisfied with the measurement, tap Accept. You

will return to the Remote Elevation screen and the base station’s

newly calculated elevation is displayed. The occupied benchmark

point has now been added to the job file as a GPS control point.

6. If the new base elevation is acceptable, tap Accept from the

Remote Elevation screen to open the Adjust with Projection
wizard, which will show a preview of the points to be adjusted,
including the update to the base position elevation. Tap Apply to
update the vertical coordinate system in the job file, and apply
the adjustment to the job file points.