beautypg.com

Spectra Precision Survey Pro v4.6 Recon and Nomad User Manual User Manual

Page 152

background image

User’s Manual – Conventional Mode

142

4. Prompts will open after every shot that instruct you

on which point to shoot next and when you when you

need to flop the scope.

If at least three sets were performed, the Average (of)
and Worst Residual fields will be filled in after the final
shot is taken. The Average (of) values are simply average
measurements for all of the shots taken. The Worst
Residual is the angle or distance measurement that

varied the most from the average from all the shots
taken.
5. Optional – The particular measurement with the

worst residual can be removed and consequently not

used when computing the coordinates for the
foresight point by tapping the corresponding Toss
button. After tossing a measurement, the Average

(of) and Worst Residual values are recomputed (assuming there is
still data from at least three shots remaining).

6. Optional – You can re-shoot the specified number of sets, and only

collect the horizontal angle, zenith angle, or slope distance from
all the shots by tapping the HA, ZA, or SD button, respectively.
This will replace all of the current shot data only for the selected

data type with new data. You can even change the number of sets
before shooting the new data.

7. Once you are satisfied with your shot data, tap Side Shot to store

the new foresight point as a side shot, or tap Traverse to store it
as a traverse shot.