Spectra Precision Survey Pro v4.6 Recon and Nomad User Manual User Manual
Page 228
User’s Manual – Leveling Mode
218
7. You can optionally tap Check H. Dist to verify the
instrument is centered between the two rods.
The distance to Point B will be measured and
compared to the horizontal distances previously
measured to Point A and a come/go distance will
be provided so the rod at Point B can be moved to
equal the horizontal distance to Point A prior to
taking the shots that will be used to compute the
error.
8. Tap Take Shot. The Leveling Shots screen will
open again and prompt you to take the required
shots to the rod over Point B. Once completed,
the Peg Test screen will open with a new graphic
showing the next setup.
9. Move the instrument as close as possible to the
rod over Point A where a shot can still be taken
to it. This is typically about 3 meters (10 feet)
from the rod.
10. Tap Take Shot. The Leveling Shots screen will
open again where you can take the required
shots to Point A from the new setup.
11. Once complete, turn to Pont B and take the
required shots to that point.