Cdaqmxaopwmlist::change, Cdaqmxaopwmlist::copy – Yokogawa PC-Based MX100 User Manual
Page 630
![background image](/manuals/360310/630/background.png)
12-66
IM MX190-01E
CDAQMXAOPWMList::change
Syntax
void change(int idAOPWM, int aopwmNo, int bValid, int
iAOPWMValue = 0);
Parameters
idAOPWM
Specify the AO/PWM data identifier.
aopwmNo
Specify the AO/PWM data number.
bValid
Specify valid/invalid using a Boolean value.
iAOPWMValue
Specify the output data value.
Description
Changes the AO/PWM data of the specified AO/PWM data identifier.
If the data identifier is set to the constant for “Specify all data identifiers,” all data in
the list is processed.
If AO/PWM data is set to the constant for “Specify all AO/PWM data numbers,” all
numbers within the data are processed.
Reference
getClassMXAOPWMData
CDAQMXAOPWMData::setAOPWM
CDAQMXAOPWMList::copy
Syntax
virtual void copy(int idxNo, int idxSrc);
Parameters
idxNo
Specify the data identifier of the copy destination.
idxSrc
Specify the data identifier of the copy source.
Description
Copies the contents of the data indicated by the data identifier from the copy source
to the copy destination.
Reference
copyData
getClassMXAOPWMData
12.4 Details of the MX100 Class