Talkoperationdatadarwin – Yokogawa PC-Based MX100 User Manual
Page 544

10-46
IM MX190-01E
talkOperationDataDARWIN
Syntax
int talkOperationDataDARWIN(DAQDARWIN daqdarwin, int
startChType, int startChNo, int endChType, int endChNo);
Declaration
Public Declare Function talkOperationDataDARWIN Lib
"DAQDARWIN"(ByVal daqdarwin As Long, ByVal startChType As
Long, ByVal startChNo As Long, ByVal endChType As Long, ByVal
endChNo As Long) As Long
Parameters
daqdarwin
Specify the device descriptor.
startChType
Specify the start channel type.
startChNo
Specify the start channel number.
endChType
Specify the end channel type.
endChNo
Specify the end channel number.
Description
Executes the declaration for retrieving setup data of the operation mode from the
start channel (start channel type and start channel number) to the end channel (end
channel type and end channel number).
• This function executes the TS and LF commands of the DARWIN communication
function.
• After executing this function, use the getSetDataByLineDARWIN function to
retrieve the data by lines.
Return value
Returns an error number.
Error:
Not descriptor
No device descriptor.
Reference
CDAQDARWIN::talkOperationData
10.1 Details of Functions - DARWIN (Visual C/Visual Basic) -