Cdaqmxconfig::setskip, Cdaqmxconfig::setstrain – Yokogawa PC-Based MX100 User Manual
Page 173

2-150
IM MX190-01E
CDAQMXConfig::setSKIP
Syntax
void setSKIP(int chNo);
Parameters
chNo
Specify the channel number.
Description
Sets the channel of the specified channel number to SKIP (not used).
If the module does not exist, the value is not set.
If the constant for “Specify all channel numbers” is specified for the channel
numbers, all channels are processed.
Reference
getClassMXChConfig CDAQMXChConfig::setSKIP
CDAQMXConfig::setSTRAIN
Syntax
void setSTRAIN(int chNo,int iRangeSTRAIN,int spanMin = 0,int
spanMax = 0);
Parameters
chNo
Specify the channel number.
iRangeSTRAIN Specify the strain range type.
spanMin
Specify the span minimum.
spanMax
Specify the span maximum.
Description
Sets the channel of the specified channel number to the specified range.
If the maximum and minimum values are the same, the span is considered omitted.
If the channel does not exist or the channel is not on the corresponding module, the
setting is void.
If the constant for “Specify all channel numbers” is specified for the channel
numbers, all channels are processed.
Resets the initial balance data.
Reference
getClassMXBalanceData
getClassMXChConfig
getClassMXSysInfo
CDAQMXBalanceData::setBalance
CDAQMXChConfig::setSpan
CDAQMXChConfig::setSTRAIN
CDAQMXSysInfo::getModuleType
CDAQMXSysInfo::getTempUnit
2.5 Details of the MX100 Class