Yokogawa PC-Based MX100 User Manual
Page 1184
![background image](/manuals/360310/1184/background.png)
24-93
IM MX190-01E
DARWIN for Extended API - Visual C/Visual Basic/Visual Basic.NET/Visual C#
24
dataStatusDA100Reader
Syntax
int dataStatusDA100Reader(DAQDA100READER daqda100reader, int
chType, int chNo);
Declaration
Visual Basic
Public Declare Function dataStatusDA100Reader Lib
"DAQDA100"(ByVal daqda100reader As Long, ByVal chType As Long,
ByVal chNo As Long) As Long
Visual Basic.NET
Public Declare Ansi Function dataStatusDA100Reader Lib
"DAQDA100"(ByVal daqda100reader As Integer, ByVal chType As
Integer, ByVal chNo As Integer) As Integer
C#
[DllImport("DAQDA100.dll" CharSet=CharSet.Auto,
EntryPoint="dataStatusDA100Reader"]
public static extern int dataStatusDA100Reader(int
daqda100reader, int chType, int chNo);
Parameters
daqda100Reader
Specify the device descriptor.
chType
Specify the channel type.
chNo
Specify the channel number.
Description
Gets the data status value of the specified channel (channel type and number) from
the stored measured data.
• If it does not exist, “Unknown” is returned.
Return value
Returns the data status value.
Reference
dataStatusDA100
24.4 Details of Instantaneous Value Loading Functions - DARWIN - Status Transition Functions