12-4
IM MX190-01E
Control Functions
Function
FIFO
Class and Member Function
Set date/time Current time
Stop
CDAQMX100:: setDateTime
Set backup valid/invalid
Continue
CDAQMX100:: switchBackup
Format of the CF card
Stop
CDAQMX100:: formatCF
Unit
Reconfigure
Stop
CDAQMX100:: reconstruct
Initialize
Stop
CDAQMX100:: initSetValue
Reset alarm
Stop
CDAQMX100:: ackAlarm
(alarm ACK)
7-segment LED display
Continue
CDAQMX100:: displaySegment
Initialize stored data
Specify channel
Continue
CDAQMX100:: initDataCh
Specify FIFO
Continue
CDAQMX100:: initDataFIFO
At the end of communications, the control function updates the status.
See the data manipulation functions for more about the data transmission and setup
functions.
Setup Functions
Function
FIFO Class and Member Function
Setup data Collectively
All setup data
Stop CDAQMX100:: sendConfig
(send collectively) Basic setup data
Stop CDAQMX100:: sendConfig
Individually
System config data
Stop CDAQMX100:: sendConfig
Channel setup data Stop CDAQMX100:: sendConfig
Initial balance data
Stop CDAQMX100:: sendConfig
Output channel data Stop CDAQMX100:: sendConfig
Initial balnc Execute
Stop CDAQMX100:: initBalance
data
Reset
Stop CDAQMX100:: clearBalance
The setup data setup functions send the data being stored.
When setting arbitrary initial balance data, see the initial balance data sending
function under data manipulation functions.