Syntax
int setPULSEDARWIN(DAQDARWIN daqdarwin, int iRangePULSE, int
chType, int startChNo, int endChNo, int spanMin, int spanMax,
int scaleMin, int scaleMax, int scalePoint, int bFilter);
Declaration
Public Declare Function setPULSEDARWIN Lib "DAQDARWIN"(ByVal
daqdarwin As Long, ByVal iRangePULSE As Long, ByVal chType As
Long, ByVal startChNo As Long, ByVal endChNo As Long, ByVal
spanMin As Long, ByVal spanMax As Long, ByVal scaleMin As
Long, ByVal scaleMax As Long, ByVal scalePoint As Long, ByVal
bFilter As Long) As Long
Parameters
daqdarwin
Specify the device descriptor.
iRangePULSE
Specify the pulse range.
chType
Specify the channel type.
startChNo
Specify the start channel number.
endChNo
Specify the end channel number.
spanMin
Specify the left value of the span.
spanMax
Specify the right value of the span.
scaleMin
Specify the left value of the scale.
scaleMax
Specify the right value of the scale.
scalePoint
Specify the decimal point position for scaling.
bFilter
Specify a filter using a boolean value.
Description
Sets the specified pulse range to the channels in the specified channel range
(specified by channel type, start channel number, and end channel number).
• With the span and scale specification, if the left and right values are the same,
they are considered omitted.
• This function executes the SR command of the DARWIN communication function.
Return value
Returns an error number.
Error:
Not descriptor
No device descriptor.
Reference
CDAQDARWIN::setPULSE
10.1 Details of Functions - DARWIN (Visual C/Visual Basic) -