E-30 – Yokogawa FieldMate User Manual
Page 80

E-30
IM 01R01A01-01E
9th Edition : May 31, 2013-00
Table E-3-3
Protocol
Import
Export
HART
All the setting parameters
All the setting parameters
FOUNDATION fieldbus
Parameters by function block
ISA100
“Upload from Device”, “Download to Device”, “Load from File”, “Save to File”, “Load from
Database”, “Save to Database” is effective only when Offline parameter window is open and
active.
Combinations in detail above are shown in the following table.
Table E-3-4
Type A DTM designed by
Yokogawa
Type B/C DTM designed
by Yokogawa
Built-in DTM
Online
Parameter
Window
Offline
Parameter
Window
Online
Parameter
Window
Offline
Parameter
Window
Online
Parameter
Window
Offline
Parameter
Window
Operation
Parameter
A
A
Ч
--
Ч
--
Ч
--
Ч
--
Upload from
device Icon
Operation
Parameter
×
--
D
Ч
--
Ч
--
Ч
--
Ч
--
Download to
device Icon
Operation
Parameter
×
--
D
Ч
--
Ч
--
Ч
--
Ч
--
Upload
from device
Button
Operation
Parameter
Ч
--
Ч
--
B
B
B
B
Download
to device
Button
Operation
Parameter
Ч
--
Ч
--
C
C
C
C
Save to File
Icon
Operation
Parameter
×
--
D
×
--
D
×
--
D
Load from
File Icon
Operation
Ч
Ч
Ч
Save to
Database
Icon *1
Operation
Parameter
×
--
D
×
--
D
×
--
D
Load from
Database
Icon *1
Operation
Ч
Ч
Ч
: Available
×: Not Available
--: Not Applicable
A: Selected Parameter
B: Parameters currently displayed in the window
C: Parameters in mazenda currently displayed in the Window
D: Area where Offline parameters are included
*
1 : Refer to PART F