beautypg.com

IAI America RCM-101-USB User Manual

Page 260

background image

14.

Appendix

248

Code

Message

Description

305 Communication error

A communication error not specified above occurred when a response

message was received from the controller.

Causes : [1] Communication fault due to poor connection between the PC

and controller

[2] Communication fault due to noise (garbled data, etc.)

Actions : [1] Check if the connectors on the PC-controller connection cable

are firmly connected.

[2] Readjust the wiring, equipment installation, etc., to eliminate

noise.

If the problem still persists, contact IAI.

306 Checksum error

A checksum error occurred when a response message was received from

the controller.

Causes : [1] Communication fault due to poor connection between the PC

and controller

[2] Communication fault due to noise (garbled data, etc.)

Actions : [1] Check if the connectors on the PC-controller connection cable

are firmly connected.

[2] Readjust the wiring, equipment installation, etc., to eliminate

noise.

If the problem still persists, contact IAI.

307 CRC error

A CRC error occurred when a response message was received from the

controller.

Causes : [1] Communication fault due to poor connection between the PC

and controller

[2] Communication fault due to noise (garbled data, etc.)

Actions : [1] Check if the connectors on the PC-controller connection cable

are firmly connected.

[2] Readjust the wiring, equipment installation, etc., to eliminate

noise.

If the problem still persists, contact IAI.

308 Receive message error

This error indicates that the response message from the controller contains

abnormal data.

Causes : [1] Communication fault due to poor connection between the PC

and controller

[2] Communication fault due to noise (garbled data, etc.)

Actions : [1] Check if the connectors on the PC-controller connection cable

are firmly connected.

[2] Readjust the wiring, equipment installation, etc., to eliminate

noise.

If the problem still persists, contact IAI.

310 Connected model not

supported

This error indicates that connection of a model not supported by the PC

software was detected.

Check the version of the PC software and models supported by the

software.

311 Baud rate specification

error (PC COM port)

This error indicates that the port could not be opened at the baud rate

specified in the “application of setting window.”

The following cause is considered:

‚

The specified baud rate is not supported by the COM port on the PC.

Change the baud rate to a supported setting.