IAI America RCM-101-USB User Manual
Page 163

11. Smart T
uning Function (V
ersion V8.03.00.00 or Later)
151
Operation
Start
Button
Click this button to start the test run.
(Note) Without clicking on
Stop button, the test run automatically finishes at the end.
(Note) In some cases of start position and end position settings, the following message may appear.
In the case this message is displayed, change the start position and end position so the
moving distance can be long enough.
Fig. 11.63 Operation Unable Message due to Moving Distance too short
(Note) The following message may appear depending on the combination of velocity and
acceleration/deceleration settings when “S Motion” is selected for the operation mode. The
message will no longer appear if the setting is changed to that with acceleration time less than
2.0 [sec] for the velocity and acceleration/deceleration.
Fig. 11.64 Compulsory Trapezoid Operation Message
(Note) The following message may appear depending on the operation settings when “S Motion” is
selected for the operation mode. Select
Yes and the test run operation can be executed. To
make the warning not to appear, change the operation setting so the acceleration time
becomes longer.
Fig. 11.65 Overshoot Warning Message
Stop Button