Modem functions – E-Mon Energy Software User Manual
Page 209

Status Bar Function Codes and Error Flag Codes
tE-Mon Energy User Manual
B-2
E-MON
18
0
Error: No connection
Lost connection before command was
complete.
19
0
Error: Time out
Did not get the proper response from
Hardware in the specified time.
20
0
Invalid cmd
An unknown command was sent to the
Hardware or security level not allowing it.
21
0
Re-download
For high resolution meter, the profile data
exceeds the max pulse limit. The day block
will be re-downloaded one more time.
22
0
Err: data over limit
At least one of the interval data exceeds the
rated pulse. Check the Meter configuration in
the database, especially the Pulse Factor.
23
0
Err: missing day block
At least one day block of interval profile data
is missing during download. The download
date will be updated.
24
0
Err: data length
The profile data block has the wrong length.
Software keeps downloading but it won’t
update the download date.
25
0
Error: recr param
During download, cannot get the recorder
parameter from database, download failed.
26
0
Error: database update
When sending Recorder or Meter information,
failed to update the database with the
information sent. Or when download failed to
update the profile to the database.
27
0
New Location! Click [Add Location] button
to setup
When a remote recorder calls-in, E-Mon
Energy™ will query the group/location from
the device, if E-Mon Energy can not find it in
the database, it will prompt you to add a
location.
28
3
STANDBY
E-Mon Energy is waiting to receive in-coming
calls (AMR). Or Access location is ready to
make the connection.
29
3 Err
or
Refer to status bar panel 0 for the cause.
Modem Functions
No
Status Loc
Status Code
Description
1
0
Modem Init Error
Transmission Modem will not dial out.
2
0
Auto Answer READY
E-Mon Energy is waiting to receive in-coming
calls (AMR).
3
0
Error in Auto Answer setup
Failed to set the modem to “not waiting” ring.
4
0
Set Dial-Timeout Error
Modem return error when sending the modem
dial timeout command.
5
0
Modem Init Timeout
Modem timeout when sending the init string
to Modem.
6
0
Bad data
Data is Corrupted.
7
0
Unexpected Data
Data Received has wrong Check Sum.
8
0
Auto Answer completed at (time stamp)
Bye command sent to Hardware .
9
0
Auto Answer terminated at (time stamp)
Other disconnection than sending Bye
command.
10
0
Auto Answer line dropped at (time stamp)
Line disconnected when neither hardware nor
software initiates the disconnection.
11
0
Register comport status’
Auto-answer synchronizes the comport status
with modem.
12
3
Initialize Modem…
Sending initialization and configuration