Pneumatic connections, Connection variants, Changing the pneumatic connectors – Burkert Type 8645 User Manual
Page 99: Configuration and function of the modules english, Chang�ing� the pneumatic connectors
ConfiGuraTion anD funCTion of The moDules
English
8645 - 99
Pneumatic connections
connection Variants
All connection variants are suitable for the same mounting bore and can be
subsequently interchanged.
Illustration: Connection variants
chang�ing� the pneumatic connectors
cAuTION!
•
•
Danger may result from loosening the pneumatic connector.
Pressure may only be connected once all the safety clamps have been attached cor-
rectly.
Pay attention that the safety clamps are fitted correctly.
Leaking connectors
can result from old, damaged or unsuitable gaskets.
Pay attention to the condition of the gaskets.
NOTE!
Take care that the seal is not damaged during assembly.
1
Legend
1 Safety clamp
Illustration: Changing the pneumatic connectors
Proceed as follows when changing the pneumatic connectors:
Pull out the safety clamps (see illlustration) using a screwdriver.
Remove the pneumatic connector.
Install the new pneumatic connector.
Reattach the safety clamps.