Rio module, Configuration and function, Technical data – Burkert Type 8645 User Manual
Page 83: General technical data, Config�uration and function, Configuration and function of the modules english
ConfiGuraTion anD funCTion of The moDules
English
8645 - 8
RIO MOduLE
config�uration and Function
The RIO module allows the system to be expanded by a
further remote 16 input and 16 output lines.
Illustration: RIO Module
Technical data
General Technical data
Operating voltage
24 V -15 % / +20 %
Residual ripple
2 Vss
Current consumption
Inputs / logic (U
L
)
Outputs (U
0
)
max. 1 A
max. 4 A (M12)
Connection
Power supply
RIO bus incoming
RIO bus outgoing
M12, plug, 4-pin, max. 4 A
M8, jack, 4-pin
M8, jack, 4-pin
Address setting
Address range
via rotary encoder switch
0 to 50
Diagnostics
Integrated diagnostic
interface
Diagnostic LEDs
-pin (RM 2.54)
2 x bus status, 2 x fault indication, x supply voltage
Material
PBT
Weight
520 g