beautypg.com

Pneumatic connections, Safety precautions, Connector assignment – Burkert Type 8645 User Manual

Page 33: Configuration and function of the modules english, Connector assig�nment

background image

ConfiGuraTion anD funCTion of The moDules

English

8645 -

Pneumatic connections

Safety Precautions

WARNING!

Danger from excessive pressure in the casings!
The safety vent on the casing allows the air to escape from the module.
It must always be connected and must never be closed off,
otherwise the protective function and type of protection are not guaranteed.

connector Assig�nment

2

4

1

Ext

Int

Ext

Int

5

6

Illustration: Pneumatic connections – Fieldbus module PROFIBUS

PROFIBUS

®

Legend

1
2
3

Auxiliary control air M5, D6, D4, D1/4“
Pilot exhaust air M5, D6, D4, D1/4“
Exhaust air G1/4“, NPT1/4“, D10

4
5
6

Compressed air supply G1/4“, NPT1/4“, D10
Safety vent M5, D6, D4, D1/4“
Switching between external / internal auxiliary control air

NOTE!

Connector 12/14 must be closed for internal auxiliary control air.