Configuration and function of the modules english – Burkert Type 8645 User Manual
Page 54
54 - 8645
ConfiGuraTion anD funCTion of The moDules
English
Object 1602 hex - 3rd Receive PdO mapping�
Mapping of the third Receive PDO.
Sub index
content
Default
Access
read
write
00 hex
Number of mapped objects of the PDO
08 hex
X
-
01 hex
PDO – mapping for the n-te object
(6200 / 11) hex
X
X
02 hex
(6200 / 12) hex
X
X
0 hex
(6200 / 1) hex
X
X
04 hex
(6200 / 14) hex
X
X
05 hex
(6200 / 15) hex
X
X
06 hex
(6200 / 16) hex
X
X
07 hex
(6200 / 17) hex
X
X
08 hex
(6200 / 18) hex
X
X
Object 1603 hex - 4th Receive PdO mapping�
Mapping of the fourth Receive PDO.
Sub index
content
Default
Access
read
write
00 hex
Number of mapped objects of the PDO
08 hex
X
-
01 hex
PDO – mapping for the n-te object
(6200 / 19) hex
X
X
02 hex
(6200 / 1A) hex
X
X
0 hex
(6200 / 1B) hex
X
X
04 hex
(6200 / 1C) hex
X
X
05 hex
(6200 / 1D) hex
X
X
06 hex
(6200 / 1E) hex
X
X
07 hex
(6200 / 1F) hex
X
X
08 hex
(6200 / 20) hex
X
X
Object 1800 hex - 1st Transmit PdO communication parameter
Sub index
content
Default
Access
read
write
00 hex
Highest supported sub index
05 hex
X
-
01 hex
COB ID used by the PDO
180 hex + Address
X
X
02 hex
”Transmission Type“; values 00 hex - FF hex
FF hex
X
X
0 hex
”Inhibit Time“ (0.1 ms)
00 hex
X
X
05 hex
”Event Timer“ (ms)
00 hex
X
X