ConfiGuraTion anD funCTion of The moDules
English
Further description the Fieldbus Node cANopen
The valve island corresponds to the ”Pre-defined device“ according to CANopen – standard V4.10. The ”De-
vice Profile 401 (I/O – Modules) V1.4“ applies to the functions and objects.
NOTE!
The terms ”address“ (abbreviated ”Adr.“) and node ID have the same meaning in this
description.
Identifier
The following IDs are used.
Object
Identfier
NMT
0 hex
SYNC
80 hex
EMERGENCY
80 hex + Address
1st TPDO
180 hex + Address
1st RPDO
200 hex + Address
2nd TPDO
280 hex + Address
2nd RPDO
00 hex + Address
rd TPDO
80 hex + Address
rd RPDO
400 hex + Address
4th TPDO
480 hex + Address
4th RPDO
500 hex + Address
TSDO
580 hex + Address
RSDO
600 hex + Address
GUARDING
700 hex + Address