beautypg.com

Pneumatic module, Configuration and function, Technical data – Burkert Type 8645 User Manual

Page 96: General technical data, Pneumatic data, General technical data pneumatic data, Config�uration and function, Configuration and function of the modules english

background image

96 - 8645

ConfiGuraTion anD funCTion of The moDules

English

PNEuMATIc MOduLE

config�uration and Function

The pneumatic module performs pneumatic functions.

Two valves each of types 6524, 6525 or 0460 can be integrated
into the module.

Illustration: Pneumatic module

Technical data

General Technical data

Operating voltage

24 V -15 % / +20 %

Current consumption per valve function
(at 24 V)
During pick-up (

≤120 ms)

lowered


≤60 mA

≤25 mA

Pneumatic connections

D4, D6, D 1/4”

Material

PBT

Weight
with /2 or 5/2-way valves
with 2 x /2-way valves


12 g
14 g

Pneumatic data

valve type

6524
3/2-way

6525
5/2-way

6524
2 x 3/2-way

0460
5/2-way pulsed,
5/3-way

Method of operation

1)

C/D

H

2 x C

H pulsed, L, N

Nominal size [mm]

4

2.5

QNn

2)

[l/min]

00

200

Opening time

)

10 % [ms]

12

15

Closing time

)

10 % [ms]

20

H = 15 / L, N = 20

Pressure range

4)

[bar]

2.5 to 7
Vacuum to 7
Vacuum to 10

2.5 to 7
Vacuum to 7
Vacuum to 10

2.5 to 7
1 to 7
Vacuum to 10

2 to 7

Output [W]

1

1

2

0.9

Output [W]
after pick-up time (<120 ms)

1/4

1/4

1/2

1/4

Displays

1 LED per valve function

1)

C=NC (normally closed), D=NO (normally open), L=APB (all parts blocked), N=APO (all parts open)

2)

Flow rate QNn value air [l/min]: Measured at +20 °C, pressure 6 bar at valve entry and 1 bar pressure difference

)

Switching times [ms]: Measured to ISO 12238

4)

Pressure data [bar]: Overpressure with respect to atmospheric pressure